Home  »  APCS. Hardware and software solutions  »  Hardware and software solutions for automation of power facilities  »  SAS/DARS systems for power facilities of Voltage Grade 110kv or less

                 

LLC EnergyindustryAvtomatization offers the following generic technical solutions for automation of power facilities with Voltage Grade below 110kV:

 

• Automated monitoring system for RPA (SCADA InDev);

• Automated emergency data processing system for data received from microprocessor devices (SCADA Oscl);

• Telemechanics / DARS;

• Operative interlocking of disconnectors (OID);

• Commercial and technical metering of electricity;

• control system for power quality;

• SAS / DARS for power facilities with Voltage Grade below 110 kV.

 

                                                                                          Automated system for protection and automation device monitoring

Automated system for RPA monitoring is implemented on the basis of  SCADA NPT InDev software complex.

 

                                                                                     Automated emergency data processing system for data from microprocessor devices

 The automated emergency data processing system for data from microprocessor devices is implemented on the basis of  SCADA NPT Oscl software complex.

 

                                                                                               List of microprocessor devices integrated into SCADA InDev и Oscl:   

    
Name  Device Name Protocol  Interface

Multifunctional measuring transducers and energy meters

Satec: BFM 136, 130 EH; Schneider Electric: ION 6200, ION 7350, ION 8500, ION 8600;

  whole SET 4TM and LFA Plus product lines  

MODBUS-RTU, MODBUS-TCP, IEC 61850, MODBUS, ION PROTOCOL

RS-485, Ethernet

Disturbance recorder and Emergency Control Automatics  

 

NEVA BRKU , Bresler-0107.010, AKA KEDR, GOSAN (BIMxXXX),

ET-8 Emergency Control Automatics, MKPA ( Prosoft Systems)  

GGI  queries, IEC 60870-5-104, IEC 61850

Ethernet

Power quality control  

Resurs  UF, Resurs UF2,

Satec PM175.

START protocol, MODBUS

RS-485,  current loop

MPU of RPA

 

Product lines: Siemens, GE, ArevaT&D, JSC Radius Automatika, LLC EKRA, JSC ChEAZ, JSC Mekhanotronika RA, MaschinefabrikReinhausen GmbH, ABB, Bresler  

 

IEC 60870-5-101 non-standard, IEC60870-5-104, IEC 61850, IEC 60870-5-104, IEC 61850, Start protocol, MODBUS, IEC 60870-5-103, IEC 61850, IEC 60870-5-103

SPABUS, IEC 60870-5-101


RS-485

Ethernet

 

DARS /Telemechanics systems for power facilities with Voltage Grade below 110kV

    Complex solution in Telemechanics/DARS, offered by LLC EnergyindustryAvtomatization includes systems for collection, processing and displaying of data, necessary for rapid centralized control of remote power facilities by means of transformation of control actions and controlled parameters into signals transmitted via communication channels.

    For power facilities with Voltage Grade 110kV, managed by JSC IDGC HOLDING, its structural subdivisions, generation companies, as well as for industrial facilities we offer several variants of the software and hardware complex.

   Our company uses two level structure of the system to achieve functionality and cost efficiency in generic solutions for Telemechanics/Telemetry and SCADA systems.

 

Middle (upper) level of the system:

  The Middle Level is formed by equipment that concentrate, process and transmit data from subordinate devices to the upper level and vice versa, as well as synchro-devices for subordinate devices.  A specific feature of Telemechanics/Telemetry and SCADA systems for small-scale facilities is combination of data integration function and transmission of Telemechanics data to the control room. These functions are performed by means of station communication and master controller in building the Telemechanics/DARS.

 

Lower level  

Lower (field) level has all the devices directly connected to the controlled facility. They provide collection of data and issue of controlling commands.

 

Features of Telemechanics/DARS system manufactured by LLC EnergyindustryAvtomatization:

  • Collection of data from distributed network power facilities in the central control room; 
  • Integration of pre-installed telemechanics from third-party manufacturers;
  • Flexible pricing;
  • Lower level devices can be chosen according to Client's wishes; 
  • Real-time mode in process control and management; 
  • Effective use of communication channels in conditions of limited frequency band in a channel; 
  • Assurance of compatibility with existing Telemechanics, operative-information complex and power facility's channel forming equipment; 
  • Assurance of equipment and software reliability in combination with optimized cost efficiency in implementaiton and service of the integrated automated system; 
  • Possibility for further extension of the system to full-scale SAS when volume of data increases.

 

 

 

Structural chart of Telemechanics/Telemetry and SCADA system

3_new.jpg 

This structural chart shows Telemetry and SCADA system without installation of Server, Automated workstation and SCADA NPT Expert at the facility. The server may be located in the control room. This provides for cost efficiency and allows data transmission directrly to the system control center or Regional Dispatching Office.

   Software and hardware solution for Telemechanics/DARS  NPT Expert provides in-time transmission of the power facility status data thus allowing rapid control of energy supply, fast detection and correction of disturbances, optimal and no-break power supply to different production areas. 

   Implementation of Telemechanics/DARS system developed by LLC EnergyindustryAvtomatization allows making power facility management more efficient and convenient.

System devices:

1) RTU NPT 3010

2) Telemechanics Controller

3) Telemechanics Automated Workstation

 

Advantages from implementation of Telemechanics/DARS system from LLC EnergyindustryAvtomatization:

 

  • Distributed nature of the system, open scalable architecture of the HSS based on common international standards (IEC 60870-5-101…4, IEC 61850);
  • Telemechanics system is easily modifiable and can be extended into a full-scale DARS/SAS;
  • Increase of data flow from the substation by means of full-scale integration of adjacent systems;
  • Low cost of system implementation, service and extension thank to use of Russian know-how.

 

Operative Interlocking of disconnectors   (OID)

 

Automated systems for technical and commercial book-keeping, electricity quality control

    Implementation of automated quality control systems, technical and commercial metering allows having operative data, controlling parameters of all the nodes in the network, finding possible cost-efficient measures. 

   LLC EnergyindustryAvtomatization uses its own HSS for engineering, development and implementaion of automated systems for commercial and technical metering and power quality control.

 

Implementation of such systems allows:

  • Assurance of information safety by means of software and hardware protection of data and use of protected protocols; 
  • Organization of parallel collection of data from all the metering stations, thus reducing poll time and data transmission time and extending system capabilities, allowing for connection of more metering stations;
  • Use of web-interface for displaying the data to user at any Internet-connected computer, including mobile devices without need to install additional software;
  • Flexible data access rules management.
  • Development of data displaying interface and report forms according to Client's wishes.
                             

                                                                           sql.jpg

 

 

 System's architecture has three levels:

  • Data and measurement level. 

The principal task is measurement of electrical energy parameters at the metering station and transmission of data via communication channel (RS-485, RS-232, GSM, radio channel, etc.) to the data collection level.

The following equipment is used by LLC EnergyindustryAvtomatization at this level:

1. To control electrical energy quality:

- Satec PM175 – smart electrical energy quality analyzer compliant with GOST 13109-97;

- Satec EM720 – metering device  and power quality analyzer compliant with GOST 13109-97; 

2. For commercial electricity metering:

- Satec PM175;

- Satec EM720.

3. For technical electricity metering:

- BFM 136 – electrical energy meter for facilities with a large number of connections with low Voltage Grade;

- Satec PM130 – digital multimeter. 

  • Data collection level. 

   The level is built upon data collection controller. The controller allows integration of microprocessor energy metering devices using different digital protocols and transmission of data to the central server. Combining Data collection level with Data processing server into a single construct is possible for small-scale facilities

  • Data processing and storage level. 

   The task of equipment and software at this level is to assure data reception from remote data collection controllers, data storage in long-term archives, logical processing and provision of access by means of web-based GUI. It is possible to combine the server with an automated workstation into a single automated workstation.

 

Software solutions developed by LLC EnergyindustryAvtomatization. 

                                                                                                                     

                                                                                                                   SAS/DARS systems for power facilities of Voltage Grade 110kv or less  

   All the hardware solutions listed above can be installed at the facility as independent systems or as parts of NPT Expert HSS. 

   By adding the top level (Server and Automated workstation) it is possible to create a full-scale SAS with functions of monitoring, control, microprocessor equipment integration support for different data-controlling subsystems (MP RPA, centralized signalling, EA, fault recorders, Automatic system for commercial metering of power consumption, etc.), that provides both remote and local user with complete interface and assures transmission of data through telemechanics channels.

                                                   asutp.jpg

 

 

 

 

   Key part of the SAS systems for facilities of Voltage Grade 110 kV and below is the software solution developed by LLC EnergyindustryAvtomatization - SCADA NPT Expert.

 

Advantages for implementation of the SAS/DARS system developed by LLC EnergyindustryAvtomatization for power facilities of Voltage Grade 110kV or less:

 

  • Low cost of supply and implementation of the SAS;
  • Generic solution for distribution as a ready-to-use product;  
  • Installation and adjustment may be performed by Client's personnel;  
  • Modular structure. Possibility of gradual increase in automation of the facility;
  • Integration of wide range of digital devices to create unified data space at the top level (MPA devices, fault recorders, process interface units, obsolet KTM controllers);
  • Merger of data from several facilities is possible;   
  • Technical support for large number of distributed networked facilities;
  • Fast implementation of the system from Design Assignment to start of industrial operation.